稿件标题: FEM analysis of the clearance between the housing body and servo control valve for the main pump of 22T hydraulic excavator
稿件作者: 怯军,刘明,赵永强,周玉祥
关键字词: Hydraulic excavator, Piston pump, FEM, Optimization design, Clearance
文章摘要: The main pump, which is currently widely used in 22-ton class hydraulic excavator in China market, is a through-drive piston pump with a displacement of 112 mL/r. It was found that there was a clearance at the interface between pump housing body and servo control valve when the machine was working in fields. The similar phenomenon was observed and oil leakage was found in a lab test. In this paper, the relationships among the clearance size, the structure of servo control valve and discharge pressure were comprehensively investigated, and the method of how to eliminate this clearance was discussed in this paper as well. Based on the FEM method, some key factors which affects the clearance size and improves the structure of design were analyzed and discussed.
收录刊物: 2014.24
稿件基金: Project supported by National Torch Plan Project (No.2012GH041448)
浏览次数: 973